As for thermal power plant...Using plant operation data, we can calculate the performance of each component in systems and grasp ongoing changes. You can determine the major decreasing factors in thermal efficiency, and evaluate how each factor influences over thermal efficiency. |
|
As for new power generation system...It is required for the power generation system that the generation efficiency is higher and operation characteristics are better. Many gas turbine systems which increased power, improved generation efficiency and decreased emissions of NOx by high humid air are proposed. We analyzed these systems under a common calculation condition, such as atmospheric condition, efficiency of equipments and combustor outlet temperature. |
|
|
Reference :Toru TAKAHASHI, Yoshinobu NAKAO and Eiichi KODA, “Analysis and Evaluation about Advanced Humid Air Turbine System, ICOPE-2007, Oct 23-27, 2007, Hangzhou, China |
|